top of page
Fire-resistant_shield_withstands…_202607031649.mp4
00:00/00:00

In a facade fire, the difference between a minor incident and a national tragedy is the core of the panel.

Fire
Safety

Facade fire safety is not just a marketing topic; it is a matter of legislation, engineering, and legal responsibility. Composite panels consist of two metal surfaces and a core between them. Plastic-based cores can cause fire to spread rapidly across the facade, leading to dense smoke and flaming particles. Mineral-based A2 Core, on the other hand, limits the spread of fire and provides the time needed for evacuation and intervention.

​

Alevler arasında gösterilen A2 Core yangın güvenliği ve A2-s1,d0 performans konsepti

The right facade material is selected not during a fire, but at the project and specification stage.

Euroclass and A2-s1, d0
fire safety

Regulations in Turkey

Facade fire safety in Turkey is regulated under the Regulation on Fire Protection of Buildings (BYKHY). Especially in high-rise buildings over 21.50 meters, the use of A1 or A2 class materials is required in exterior facade systems.

A2 Core enables the production of panels that comply with this requirement by meeting the A2-s1, d0 class.

According to the EN 13501-1 standard, building materials are classified from A1 to F.

  • A2 — very limited contribution to fire development

  • s1 — lowest smoke production

  • d0 — no flaming droplets or particles during the test period

The A2-s1, d0 class met by A2 Core is one of the highest levels of fire safety achievable for facade systems.

Global requirements

Non-combustible or limited-combustible facade systems are increasingly becoming mandatory for high-rise and mid-rise buildings in major markets such as the European Union, the United Kingdom, Gulf countries, Australia, and the USA.

Lessons learned from real fires

The Grenfell Tower, Address Hotel, Lacrosse Apartments, Torch Tower, and Marco Polo fires demonstrated how quickly combustible core facade panels can spread fire. Following these incidents, facade regulations have been tightened worldwide.

A2 Core offers technical documentation regarding the following standards for specification and compliance processes:

  • EN 13501-1: A2-s1, d0

  • DIN 4102-7

  • NFPA 285

  • BYKHY compliance

Test reports, technical documents, and project-specific compliance letters are provided upon request.

Project teams looking for A2-class core panels in their specifications should contact Turbond for composite panels produced with A2 Core.

For architects and engineers

bottom of page